프로젝트 설명

펄스(Pulse) Data Logger

SmartReader Plus 9

ACR, 데이터로거, 펄스 데이터로거, 펄스 기록계, 펄스 측정, 펄스 기록, Pulse

Product

스마트리더플러스 9는 펄스2채널 Data Logger입니다.

Specifications

Range 4095 pulses/sample period
Accuracy +/- 1 pulse/sample period
Input Voltage Low = 0 to 0.5 volts DC
High = 4.5 to 24 volts DC
Input Impedance > 1.0 M ohm for Vin < 5V
> 4.0 K ohm for Vin > 5V
Min. Pulse Width 50% Duty Cycle:
Slow input: 2 milliseconds
Fast input: 10 microseconds
Maximum Frequency 100 KHz
Switch Inputs Input Type: Uncommitted “dry” contacts (relay or switch)
Excitation: 5 microamps contact current
3.6 volts open circuit
Contacts: Sealed gold-plated recommended

Common Specifications Across Models

Size 107 x 74 x 22mm (4.2 x 2.9 x 0.9in)
Weight 110 grams (3.75 ounces)
Case Material Noryl® Plastic
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy +/-2 seconds per day
Battery 3.6 volt Lithium, 1 Amp-Hour
Power Consumption 5 to 10 microamps (continuous)
Battery Life 10-year warranty (under normal use) factory replaceable
Memory Size 32 K (21,500 readings)
128 K (87,000 readings)
1.5 MB (1,000,000 readings)
See specific models for availability
Sampling Method 1. Continuous (First-in, First-out); not available with sample rates faster than 8 seconds
2. Stop when full (Fill-then-stop)
Sampling Rate User selectable rates from 25 per second to one reading every 8 hours. (BP-101 battery pack or PS-201 Power Supply required for sample rates faster than 8 seconds. See Accessories section for details.)
Resolution 12 bit (1 part in 4096)
PC Requirements Windows PC with a least 256MB RAM, 250MB of hard drive space and one free serial or USB port
Software Requirements TrendReader® 2 (compatible with Windows® XP, Vista, Windows 7, Windows 8 & Windows 10)
Product Approvals Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/ Burst and Radiated Emissions respectively for the Commission of the European Communities (CE)
Resistance to X-Rays Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 – 28 curies @ 30 second exposure source to object distance 5″